SENSOFIT INS 1310

Insertion assembly for all-purpose applications in various industries

  • For use with Ø12 / 120 mm or Ø0.47 / 4.7" sensors
  • Sensor connection: PG13.5; Process connection: INGOLD G1¼ (coupling nut)
  • Insertion length: 70 mm / 2.75"
  • Max. +140°C / +284°F and 10 bar / 145 psi

SENSOFIT INS 1310

Insertion assembly for all-purpose applications in various industries

  • For use with Ø12 / 120 mm or Ø0.47 / 4.7" sensors
  • Sensor connection: PG13.5; Process connection: INGOLD G1¼ (coupling nut)
  • Insertion length: 70 mm / 2.75"
  • Max. +140°C / +284°F and 10 bar / 145 psi

Overview

The SENSOFIT INS 1310 is a static insertion assembly for all-purpose applications in various industries. Its stainless steel (1.4404 / 316L) construction with Ra <0.8 is also made for use in hygienic environments. The housing is suitable for all Ø12 / 120 mm or Ø0.47 / 4.7″ sensors with sensor connection PG13.5. It comes with INGOLD connection (G114 coupling nut with 28 mm / 1.1″ O-ring position) to be installed into tanks and pipes.

Product features and options depend on device configuration: Contact us to make sure that your preferred functionality can be combined in one device.

  • Sealings: EPDM (incl. FDA/USP VI certificate) or FPM
  • Surface finish Ra<0.8
  • Material: Stainless steel (1.4404 / 316L)
  • Protection cap for cable connection
  • Optional sensor protection cage

Related products

SMARTPAT PH 8150

Potentiometric pH sensor for chemicals and industrial wastewater applications

  • 2-wire loop powered, 4…20 mA/HART® 7, for direct connection to a PCS
  • Process connection: PG13.5
  • 0…14 pH; Max. +130°C / +266°F; 12 bar / 174 psi
  • Glass sensor with open diaphragms and Pt1000 for temperature compensation

SMARTPAT PH 8320

Potentiometric pH sensor for water and wastewater applications

  • 2-wire loop powered, 4…20 mA/HART® 7, for direct connection to a PCS
  • Process connection: PG13.5
  • 0…14 pH; Max. +70°C / +158°F; 10 bar / 145 psi
  • Glass sensor with PTFE diaphragm and Pt1000 for temperature compensation

SMARTPAT PH 8530

Potentiometric pH sensor for pure water and low conductivity media (>2 μS/cm)

  • 2-wire loop powered, 4…20 mA/HART® 7, for direct connection to a PCS
  • Process connection: PG13.5
  • 0…14 pH; Max. +80°C / +176°F; 12 bar / 174 psi
  • Glass sensor with 3 ceramic diaphragms and Pt1000 for temperature compensation

SMARTPAT PH 8570

Potentiometric pH sensor for food, beverage and pharmaceutical applications

  • 2-wire loop powered, 4…20 mA/HART® 7, for direct connection to a PCS
  • Process connection: PG13.5
  • 0…14 pH; Max. +140°C / +284°F (SIP/CIP); 12 bar / 174 psi
  • Autoclavable glass sensor with ceramic diaphragm and Pt1000 for temperature compensation

SMARTPAT ORP 8150

Potentiometric ORP sensor for chemicals and industrial wastewater applications

  • 2-wire loop powered, 4…20 mA/HART® 7, for direct connection to a PCS
  • Process connection: PG13.5
  • -1500…+1500 mV; Max. +130°C / +266°F; 12 bar / 174 psi
  • Glass sensor with platinum electrode, open diaphragm and Pt1000 temperature sensor

SMARTPAT ORP 8510

Potentiometric ORP sensor for water and wastewater applications

  • 2-wire loop powered, 4…20 mA/HART® 7, for direct connection to a PCS
  • Process connection: PG13.5
  • -1500…+1500 mV; Max. +70°C / +158°F; 2 bar / 30 psi
  • Glass sensor with platinum electrode, ceramic diaphragm and Pt1000 temperature sensor

OPTISENS PH 8100

Potentiometric pH sensor for chemicals, industrial wastewater and low conductivity media (>2 μS/cm)

  • For use with analytical transmitter
  • Process connection: PG13.5
  • 0…14 pH; Max. +130°C / +266°F; 10 bar / 145 psi
  • Glass sensor with 2 open diaphragms and Pt100 for temperature compensation

OPTISENS PH 8300

Potentiometric pH sensor for wastewater, surface and process water applications

  • For use with analytical transmitter
  • Process connection: PG13.5
  • 0…14 pH; Max. +70°C / +158°F; 10 bar / 145 psi
  • Glass sensor with PTFE diaphragm and optional Pt100 for temperature compensation

OPTISENS PH 8500

Potentiometric pH sensor for potable water applications

  • For use with analytical transmitter
  • Process connection: PG13.5
  • 0…14 pH; Max. +70°C / +158°F; 2 bar / 30 psi
  • Glass sensor with ceramic diaphragm and optional Pt100 for temperature compensation

OPTISENS PH 9100

Potentiometric pH sensor for lower conductivity water applications (>20 μS/cm)

  • For use with analytical transmitter
  • Process connection: PG13.5
  • 0…14 pH; Max. +100°C / +212°F; 1 bar / 14 psi
  • Liquid electrolyte glass sensor with open glass sleeve diaphragm

OPTISENS PH 9500

Potentiometric pH sensor for lower conductivity water applications (>50 μS/cm)

  • For use with analytical transmitter
  • Process connection: PG13.5
  • 0…14 pH; Max. +100°C / +212°F ; 1 bar / 14 psi
  • Liquid electrolyte glass sensor with 3 ceramic diaphragms

SENSOFIT MOUNT 1000

Mounting assembly for applications in various industries

  • For use with retractable or insertion assemblies into pipes and tanks
  • Assembly connection: G1¼ (male); Process connection: Socket weld
  • Straight or inclined version
  • Max. +140°C / +284°F and 16 bar / 232 psi
Email
Contact